Values
|
Units
|
Test
|
|
Physical |
|
|
|
|
Density
|
1.27
|
g/cm³
|
DIN
53479
|
|
Moisture
absorption: |
|
|
|
|
- 23°C,
24h immersion (3 mm) |
0.2
|
%
|
|
|
Index of
refraction n D at 20°C |
1.57
|
|
DIN
53491
|
|
Light
transmittance (2 mm sheet) |
88
|
%
|
DIN 5036
|
|
|
|
|
|
Mechanical |
|
Tensile
stress at yield |
50
|
N/mm²
|
DIN
53455 (1)
|
|
Elongation
at yield |
5
|
%
|
DIN
53455 (1)
|
|
Tensile
strength |
26
|
N/mm²
|
DIN
53455 (1)
|
|
Elongation
at break |
>100
|
%
|
DIN
53455 (1)
|
|
Tensile
modulus of elasticity |
2050
|
N/mm²
|
DIN
53457 (2)
|
|
Limiting
flexural stress |
77-83
|
N/mm²
|
DIN
53452
|
|
Impact
strength: |
|
|
|
|
- Charpy
unnotched |
no break
|
J/m²
|
DIN
53453
|
|
- Charpy
notched |
16
|
J/m²
|
DIN
53453
|
|
- Izod
notched (4 mm) |
90
|
J/m
|
ASTM
D256
|
|
Instrumented impact (4 mm) at F max |
28
|
J
|
ASTM
D3763
|
|
Rockwell
hardness |
R104-R117
|
rating
|
ASTM
D785
|
|
|
|
|
|
Thermal |
|
Glass
transition temperature |
81
|
°C
|
|
|
Thermal
conductivity (l) |
0.32
|
W/m°C
|
DIN
52612
|
|
Coeff. of
linear thermal expansion |
0.050
|
mm/m°C
|
|
|
Heat
deflection temperature under load acc. to SO/R75 |
DIN
53461
|
|
- method
A: 1.81 N/mm 2 |
63
|
°C
|
|
|
- method
B: 0.45 N/mm 2 |
70
|
°C
|
|
|
Max.
service temperature in air (3) |
65
|
°C
|
|
|
Min.
service temperature |
-40
|
°C
|
|
| |
|
|
|
|
Electrical |
|
Dielectric
strength (4) |
20
|
Kv/mm
|
IEC
243-1
|
|
Volume
resistivity |
1015
|
Ohm.cm
|
DIN
53482
|
|
Surface
resistivity |
1016
|
Ohm
|
DIN
53482
|
|
Dielectric
constant at 10³ Hz |
2.6
|
-
|
DIN
53483
|
|
Dielectric constant at 106
Hz |
2.4
|
-
|
DIN
53483
|
|
Dissipation factor at 10³ Hz |
0.005
|
-
|
DIN
53483
|
|
Dissipation factor at 106
Hz |
0.020
|
-
|
DIN
53483
|
| |
|
|
|
|
Fire behaviour (5) |
|
Oxygen
index |
26
|
%
|
ASTM
D2863
|
|
Flammability (3 mm sheet) |
V-2 (6)
|
rating
|
UL 94
|
|
Glow wire
test (2 & 3 mm) |
850
|
°C
|
IEC695-2-1
|
|
Germany
|
|
|
|
|
- 0.5 to 8
mm sheet |
B1
|
rating
|
DIN
4102/part1
|
|
- 4 mm
sheet |
S4/SR2/ST1
|
rating
|
DIN 5510
DIN
|
|
- 5 & 6 mm
sheet |
S4/SR2/ST2
|
rating
|
5510
|
The
above-mentioned values are typical values at 23°C, unless otherwise
stated. They are intended as a guideline for material determination.
They cannot be used for drawing up material specifications. They do
not discharge the user of effecting his own tests in order to
determine whether a material is suitable for the application.
- Test
speed: 50 mm/min.
- Test
speed: 5 mm/min.
-
Temperature resistance over a period of several months to several
years. The given temperature limits are determined by the
thermal-oxidative degradation which takes place and causes a
fall-off in properties (embrittlement). Besides, as for all
thermoplastics, the maximum service temperature depends essentially
on the duration and the magnitude of the mechanical stress to which
the material is subjected.
-
Measured on a 2 mm thick test specimen. As with other materials, the
dielectric strength diminishes with increasing sheet thickness, e.g.
for 3 mm sheet the dielectric strength is 16 kV/mm, for 6 mm sheet
11 kV/mm.
-
These ratings are not intended to reflect hazards presented by the
material under actual fire
-
Classification obtained on the resin
|