> General PETG Information


 
Values
Units
Test
Physical
 
 
 
Density
1.27
g/cm³
DIN 53479
Moisture absorption:
 
 
 
- 23°C, 24h immersion (3 mm)
0.2
%
 
Index of refraction n D at 20°C
1.57
 
DIN 53491
Light transmittance (2 mm sheet)
88
%
DIN 5036
Mechanical
Tensile stress at yield
50
N/mm²
DIN 53455 (1)
Elongation at yield
5
%
DIN 53455 (1)
Tensile strength
26
N/mm²
DIN 53455 (1)
Elongation at break
>100
%
DIN 53455 (1)
Tensile modulus of elasticity
2050
N/mm²
DIN 53457 (2)
Limiting flexural stress
77-83
N/mm²
DIN 53452
Impact strength:
 
 
 
- Charpy unnotched
no break
J/m²
DIN 53453
- Charpy notched
16
J/m²
DIN 53453
- Izod notched (4 mm)
90
J/m
ASTM D256
Instrumented impact (4 mm) at F max
28
J
ASTM D3763
Rockwell hardness
R104-R117
rating
ASTM D785
Thermal
Glass transition temperature
81
°C
 
Thermal conductivity (l)
0.32
W/m°C
DIN 52612
Coeff. of linear thermal expansion
0.050
mm/m°C
 
Heat deflection temperature under load acc. to SO/R75
DIN 53461
- method A: 1.81 N/mm 2
63
°C
 
- method B: 0.45 N/mm 2
70
°C
 
Max. service temperature in air (3)
65
°C
 
Min. service temperature
-40
°C
 
       
Electrical
Dielectric strength (4)
20
Kv/mm
IEC 243-1
Volume resistivity
1015
Ohm.cm
DIN 53482
Surface resistivity
1016
Ohm
DIN 53482
Dielectric constant at 10³ Hz
2.6
-
DIN 53483
Dielectric constant at 106 Hz
2.4
-
DIN 53483
Dissipation factor at 10³ Hz
0.005
-
DIN 53483
Dissipation factor at 106 Hz
0.020
-
DIN 53483
       
Fire behaviour (5)
Oxygen index
26
%
ASTM D2863
Flammability (3 mm sheet)
V-2 (6)
rating
UL 94
Glow wire test (2 & 3 mm)
850
°C
IEC695-2-1
Germany
 
 
 
- 0.5 to 8 mm sheet
B1
rating
DIN 4102/part1
- 4 mm sheet
S4/SR2/ST1
rating
DIN 5510 DIN
- 5 & 6 mm sheet
S4/SR2/ST2
rating
5510
 
The above-mentioned values are typical values at 23°C, unless otherwise stated. They are intended as a guideline for material determination. They cannot be used for drawing up material specifications. They do not discharge the user of effecting his own tests in order to determine whether a material is suitable for the application.
  1. Test speed: 50 mm/min.
  2. Test speed: 5 mm/min.
  3. Temperature resistance over a period of several months to several years. The given temperature limits are determined by the thermal-oxidative degradation which takes place and causes a fall-off in properties (embrittlement). Besides, as for all thermoplastics, the maximum service temperature depends essentially on the duration and the magnitude of the mechanical stress to which the material is subjected.
  4. Measured on a 2 mm thick test specimen. As with other materials, the dielectric strength diminishes with increasing sheet thickness, e.g. for 3 mm sheet the dielectric strength is 16 kV/mm, for 6 mm sheet 11 kV/mm.
  5. These ratings are not intended to reflect hazards presented by the material under actual fire
  6. Classification obtained on the resin

Atlas Plastics and Fabrication Ltd, Unit 4, Chanters Industrial Estate, Atherton, Manchester, M46 9BE, Tel. (01942) 877446 / Fax. (01942) 877477